Know-how

Stellard Entry access control (beta)

With Stellard Entry access control, your customers open the store door without a key: the Stellard device Entry reads the card and releases the door opener. The product overview with prices is at Stellard Entry access control.

The Stellard device Entry and the system are available as a beta version. We are continuously extending the features; individual workflows may still change before the final version.

Subscription plans

  • Stellard Entry Basis (available now): access via the NFC reader. Card data is not stored and is not available for later analysis. Customer registration is not yet possible.
  • Stellard Entry Standard (coming soon): your customers register once via the scango.ch web app. Registration is confirmed by SMS (charged). They then receive an access QR code, store it in their wallet and scan it at the Stellard device Entry. The Stellard device Entry can also be deactivated at set times.

The plan requires a scango.ch subscription «Basis» or higher. The minimum term is 12 months, then it can be cancelled monthly. Support is provided by e-mail ticket only.

Dimensions

Device with a customer-facing display, mounted at the entrance (on a pipe or directly on the wall).

Height24.6 cm
Width10.2 cm
Depth8.1 cm
Display5.5-inch colour LCD
Weight570 g (without pipe clamp)

Technical data

  • Customer-facing display (5.5-inch colour LCD)
  • Code scanner for 1D and 2D codes including QR codes
  • NFC reader (13.56 MHz)
  • Ethernet (100 Mbps), network connection required on site
  • 230 V power adapter included
  • Software pre-installed

Connecting the door opener

Sketch: the Stellard device Entry controls the relay via Wi-Fi, the relay switches the door opener

The Stellard device Entry does not open the door itself. The door is released via a relay (Shelly 1 Gen4), which is included in the price. The Stellard device Entry controls the relay via Wi-Fi, so you can place the relay independently of the device during installation, for example right next to the door opener.

The relay switches a potential-free contact, like a push button. Potential-free means the contact carries no voltage of its own; it only connects two wires. It can switch up to 16 A at 240 V~ or 10 A at 30 V⎓.

  • The relay needs its own power supply (110–240 V~, 24–48 V⎓ or 12 V⎓) and is rated for -20 °C to 40 °C.
  • You make sure your door opener or electronic lock can be controlled via such a contact, for example via a push-button input.
  • The relay's power supply and its connection to your door opener are done by a qualified electrician you appoint; they are responsible for it.
  • The power supply of relay and lock is not part of the Stellard device Entry.

Setting up the relay

Connect the relay to your store's Wi-Fi, in the same network as the Stellard device Entry. Then give it a fixed IP address: in the router (DHCP reservation) or as a static address in the Shelly's Wi-Fi settings (web interface or Shelly app).

Then select the relay in the scango.ch dashboard under Devices for the Stellard device Entry:

  1. Open the device settings and, in the Door opener section, turn on "Open the door with a Shelly relay".
  2. In the Find a Shelly on the network box, click Search the network. The device searches its own network: it picks the request up within a minute, the search then takes a few seconds.
  3. Click Use next to the right Shelly and save. This fills in the "IP address of the Shelly".

If you select the Shelly through the search, the device remembers its identifier (MAC address). With it, the device:

  • checks before opening that it really is this relay that answers at the address. It never switches a different relay, for example the one of another door.
  • finds the relay again in its network if the address changes. It checks this every two minutes, and right away if it cannot reach the relay when opening. It uses the new address provisionally; the device settings show a notice with Use new address. Use it, save and give the relay a fixed address.

You can also enter the "IP address of the Shelly" by hand. The device does not check an address entered this way: if it changes, the Stellard device Entry can no longer reach the relay and the door does not open.

The device only searches its own network. If the relay is on a different Wi-Fi (for example the guest Wi-Fi), the device does not find it. Then connect it to the device's network.

Emergency opening and escape route

The Stellard device Entry has no emergency opening function. The door itself must always be openable from the inside, even without power or network, for example:

  • a mechanical door with a handle that opens from the inside; if it opens outwards, the lock must also be designed for this
  • a sliding door whose door control handles the emergency opening

If power or the network fails, the Stellard device Entry cannot release the door. Check with your professional how the lock then behaves and what your door must provide.

Mounting

Scope of delivery

Included:

  • Stellard device Entry, software pre-installed
  • Pipe clamp
  • 230 V power adapter
  • Shelly 1 Gen4 relay

Not included, provided by you or your professional:

  • Pipe or pipe bracket with wall plate
  • Screws, wall plugs and other fixing material
  • Concealed cable routing (in the pipe, in the wall or in a cable duct) and network cable
  • Power supply for relay and lock, and the cable from the relay to the door opener

There is no separate wall mount or mounting frame. The device is always fixed via the mounting rails on its back (photo further down, no. 1).

On site it always needs:

  • a 230 V connection (socket for the supplied power adapter)
  • a network connection (Ethernet cable)
  • Wi-Fi at the relay as well as power for relay and lock
Sketch: Stellard device Entry on an L-shaped pipe bracket (not included), seen from above, and alternatively directly on the wall

The Stellard device Entry is built to be fixed to a vertical pole. We therefore recommend an L-shaped pipe bracket at the entrance. The pipe and wall plate are not included; your professional makes or orders them.

  • A wall plate is anchored to the wall. The pipe projects horizontally from the wall and bends upwards.
  • The supplied pipe clamp is screwed to the mounting rails on the back of the device and holds it on the vertical part of the pipe. The display faces the direction your customers come from.
  • This way the device stands off the wall and is visible from afar, even when people walk along the façade towards the entrance.
  • The cables leave the device at the bottom. The neatest solution is to run them inside the pipe to the wall; this protects them and makes them hard to reach.
  • The pipe clamp can be adjusted to the pipe diameter within a certain range. Your professional checks with the supplied pipe clamp whether a pipe fits before making or ordering the bracket.

Alternative: directly on the wall

Depending on the location, you can also mount the device directly on the wall. There is no separate wall mount for this: your professional screws the device to the wall via the mounting rails on its back or via the supplied pipe clamp, using fixing material suited to the wall. They take the drill-hole positions directly from the delivered device.

The display is then parallel to the wall and less visible from the side. Choose a spot where your customers walk straight towards the device.

The cables (230 V and Ethernet) leave the device at the bottom and are not protected by a pipe when wall-mounted. Plan with your professional how to conceal them, for example in the wall, in a cable duct or behind a cover. Cable routing and covers are not included; they are your or your professional’s responsibility.

Back of the device

Photo: back of the Stellard device Entry with mounting rails, connection area, cable routing and service buttons
  1. Mounting rails (part of the device, not a separately supplied part): this is where the supplied pipe clamp is screwed on or the device is fixed directly to the wall. The pipe clamp is not attached in the photo.
  2. Connection area with the plug connectors
  3. Cable routing downwards
  4. Service buttons: for support only, not for your customers

Who mounts it

Mounting is not carried out by scango.ch: mounting, cable routing, connecting and coupling to an existing access mechanism are done by you or a qualified professional you appoint. They are also responsible for secure fastening.

Weather and warranty

The Stellard device Entry must not be exposed to the weather (rain, snow, strong sunlight). The warranty is 1 year (bring-in). If the device is exposed to the weather, opened or tampered with, the warranty is void.